Aquarium heater helps to maintain warm and stable water temperature, which is critically crucial for tanks, like tropical fish tanks. In our guide below, we will cover common troubleshooting of hygger aquarium heaters, along with how to repair the heater and how to set a heater’s temperature. After reading, you will know more about aquarium heater fixes.
Common troubleshooting of aquarium heaters
To begin with, we will list the common troubleshooting of aquarium heaters:
- Improper placement
- Excess temperature
- Too low temperature
- Temperature difference
- Over voltage fault
- Sensor fault
- Components fault
Besides that, sometimes you may be confused about the error codes. Consequently, next, we will share some specific examples.
1.001 Submersible Aquarium Heater
Error code | Causes |
E1 | The aquarium heater is exposed to the air |
HH | The water temperature is above 95℉ |
EE | There is a 5° temperature difference detected by the two sensors |
E4 | Over voltage fault |
H1 H2 E2 E3 | The temperature sensor is short-circuited protection |
2.003 Variable Frequency Aquarium Heater
Error code | Causes |
LL | No.1 temperature sensor fault |
HH | No.2 temperature sensor fault |
E1 | The heater is out of water |
E2 |
|
E3 |
|
E4 | Flat power grid interference |
3.007 Quartz Submersible Aquarium Heater
Error code | Causes |
E1 | The aquarium heater is exposed to the air |
HH | The water temperature is above 95℉ |
EE | There is a 5° temperature difference detected by the two sensors |
H4 | Over voltage fault |
H1 H2 E2 E3 | The temperature sensor is short-circuited protection |
4.011 Smart Aquarium Heater
Error code | Causes |
Er & beeping | The heater is out of water/Sensor fault |
Water temperature flashing & beeping | The water temperature is above 96.8℉ & poor water circulation or improper placement of the heater |
Ec | Components fault |
E3 | Relay fault |
H1/H2 | Temperature sensor fault |
White or yellow dirt adheres | Incrustation scale |
5.045 Tiny Titan Water Heater
Error code | Causes |
Er | The heater is out of water |
EE flash | The temperature is above 95℉ |
The heater turns red indication when it is out of water | Failure of the out water shutoff function |
The heater is working but can not reach the setup temperature | The ambient temperature is below 50℉ |
H1 | Probe is broken |
H2 | Probe is broken |
E1 | Probe is broken |
E2 | Probe is broken |
E8 | Probe is broken |
EL | Reminder after 10,000 hours of use |
6.060 Ultra Short Aquarium Quartz Heater
Error code | Causes |
LL | The temperature is lower than 59℉ (15℃) |
HH | The temperature reaches 95℉ (35℃) |
EE | Sensor fault |
L1 | The heater is out of the water and exposed to air |
7.921 Aquarium Water Heater
Error code | Causes |
ER | The heater is exposed to air |
EE | Water temp exceeds about 97°F |
H1 | Temp sensor one is short-circuited protection |
H2 | Temp sensor two is short-circuited protection |
E1 | Temp sensor one is open-circuit protection |
E2 | Temp sensor two is open-circuit protection |
E3 | The relay is melted |
8.969 hygger aquarium heater
Error code | Causes |
Er | The heater is exposed to air |
EH | The water temperature is above 97℉ |
Ec | Communication failure |
E3 | The relay is melted |
H1 | Temp sensor is short-circuited protection |
How to repair an aquarium heater
In this segment, we will list remedies for some common heater faults.
Faults | Solutions |
The temperature is below the minimum level (too low temperature) | Increase the water/room temperature (e.g. add another aquarium heater/warm water for water changes/open heating fan/add an aquarium heating blanket) |
The temperature reaches the maximum level (excess temperature) | Decrease the water/room temperature (e.g. open the air condition/open the cooling fan/add float ice packs in the water/avoid direct sunlight) |
Sensor fault | Return the heater |
The heater is exposed to air or out of the water (improper placement) | Fully submerge the heater in the water |
5° temperature difference detected by sensors | Discard the heater |
Over voltage fault | Discard the heater |
The temperature sensor is short-circuited or open-circuit protection | Discard the heater |
Several degrees of differences between the water temp and the desired temp | Place the heater on the tank with great water circulation (e.g. the stream of a powerhead/the inlet or outlet of the aquarium filter/water pump) |
Components fault | Check whether the water temp is over the maximum level or not. If it is above the maximum point, discard the heater. |
Flat power grid interference | Restart |
Relay fault | Re-plug in. If the heater can not be restored, then discard it. |
Incrustation scale | Rinse the heater with clean water |
How to set an aquarium heater’s temperature
Additionally, how to set an aquarium heater’s temperature? Take a fully submersible heater as an example, you can set the desired temperature easily by pressing the “SET” button, and you can choose between 59 and 93℉. Provided that your set temp is 82℉, the heater will shut off automatically once the temp reaches the set point. Moreover, while heating, the light on the display will flash. And it will stop flashing once it reaches the set temp.
Reminder
If you want to get an aquarium heater, you should refer to the chart of the recommended tank and heater size, then you can choose the most suitable heater for your aquarium. Also, for safety during the cleaning process, you should unplug the heater first and leave it in the tank until it is cooled.
That’s all for today. For additional questions about hygger aquarium heaters, welcome to leave messages in the comment or contact us. We are happy to help you out. Finally, thanks for your time.
Hello, I purchased my double quartz 300w about a year ago. I came home today to it beeping with error code hh. Is there away to reset or repair the temp sensor?
Hi Brandon Sparks,
For the issue, hygger customer service will reach out to you and help you solve it.
We will be waiting for a reply from your mail.
Thanks
hygger team
I have a hygger tiny titan. It will read that it’s 80 degrees, but it’s only 73. This started recently. It was working fine for 3 months. Maybe there is an air bubble in it or something? I did put in a bubbler next to it.
Hi Jennifer J Kohl,
For the issue, hygger customer service will reach out to you and help you solve it.
We will be waiting for a reply from your mail.
Thanks
hygger team
I have a HG031-25W I bought in June of this year. Recently, the heater’s thermometer says the temperature is always 70F when the desired temperature is 76F. Therefore, the red LED indicator is always on. When I take the temperature of the aquarium water with a infrared thermometer gun – the tank reads around 74F. I feel it is not safe to have this heater in my aquarium if it’s always going to be on and cannot display the temperature properly.
Hi Nate,
For the issue, hygger customer service will reach out to you and help you solve it.
We will be waiting for a reply from your mail.
Thanks
hygger team
My heater looked like it was error coding EL, but it was fully submerged. Thankfully I happened to look at it just as it started flashing for no reason. Is there a fix, or is it toast?
Please advise.
Hi Jessica Porcelli,
For the issue, hygger customer service will reach out to you and help you solve it.
We will be waiting for a reply from your mail.
Thanks
hygger team
Hi, I have a hygger HG019 double quartz heater brought in March this year the red and green LED temperature indicator lights are not working but the digital display is still working. Do you know if there is a solution to this problem?
Hi Stuart Legge,
For the issue, hygger customer service will reach out to you and help you solve it.
We will be waiting for a reply from your mail.
Thanks
hygger team
Good mornign,
I have a HG060 (300w) bought about a couple of years ago.
Everythig went fine until I changed my acquarium. I put the heater in the new tank, under water level, and plugged the power line.
Now the display ever says “L1” even if it’s completely submerged.
Is there something I can check? I’m really happu with your product and I wouln’t change it until it’s definitely “dead”.
Thanks Fabio
Hi Fabio Macri,
For the issue, hygger customer service will reach out to you and help you solve it.
We will be waiting for a reply from your mail.
Thanks